HRG Production Technology
HRG Calibration, Tuning and Testing
High-precision adjustment, calibration and testing of hemispherical resonator gyroscopes (HRG) using dedicated MEDICON test and calibration systems.
Operations Performed
Installation of HRG control electronics and initial sensor tuning
Performance verification in Force-To-Rebalance and Whole Angle modes
Electronic parameter adjustment
Vibration testing
HRG operating mode optimization
Final calibration and quality inspection
Temperature testing
Test Equipment
Testing Facilities

Three-Axis Test Stand with Thermal Chamber
Designed for thermal, functional and dynamic testing of HRG systems. Enables simulation of real operating conditions encountered in navigation applications.

HRG Calibration and Adjustment Workstation
Used for resonator tuning, electronics adjustment and verification of gyroscope performance throughout the entire production process.
Advantages
Advantages
Complete testing cycle performed in-house
Parameter verification at every production stage
Temperature testing using a dedicated environmental test stand
Support for Free Wave and Force-To-Rebalance operating modes
Automated processing of measurement results
Final calibration prior to customer delivery
Result
Final Result
Upon completion of testing, every HRG undergoes final performance verification and compliance confirmation according to customer requirements before proceeding to the next production stage or shipment.